http://SAMIRIKAROOFING.IN
SAMIRIKA 58d1055f841d81080c3cfc13 False 2826 10
OK
background image not found
Found results for
'wide range'
PUF PANELS INSULATED PANELS INR   1225 INR  1225
-0%

PUF PANELS INSULATED PANELS

We manufacture PUF sandwich panel for wall, false ceiling and roof panel at Vadodara based factory. The raw material used for manufacturing PUF panel is CFC free and fire retarded grade. PUF Sandwich panels are available with pre coated GI sheets, SS sheets or as directed. Company Name: Wan-hua Chemical Material: ISO-POLIO Material Combination Make Polyurethane Foam Material 30mm – 150mm thick Polyurethane Insulation of 40 kg/m³ density sandwiched in Between two colors coated PPGL-PPGI profiled sheet and Plain sheet Technical Specification • Density: 40± Kg/cu. • Compressive Strength at 10% deformation : 2.1 Kg/sq.cm • Tensile Strength: 4.0 Kg/sq.cm • Bending Strength: 4.2 Kg/sq.cm • Adhesion Strength (Foam to steel) : 3.0 Kg/sq.cm • Dimensional Stability (48 hours) : 0.1% -25°C :0.1% 38°C & 90% RH : 0.4% • Closed Cell Content: 90-95% • Temperature Range: -18° to 140°C • Temperature Conductivity At 0°C : 0.018 k Cal/hr.m°C (design value 0.020 k Cal/m °C or 0.023 w/m k) • Water Absorption: 0.2% volume at 100% RH

INR 1225 INR 1225

Availability:True

Pay mode:COD only

view details
GLASSWOOL INSULATION INR   350 INR  350
-0%

GLASSWOOL INSULATION

One of the best known products for thermal & acoustic insulation, Glasswool is light gold in colour and is a light weight, compressible insulation material consisting of fine, long, inorganic glass fibers bonded together by a high temperature binder. Glasswool is available in rolls, slabs and boards, in various densities and thicknesses and with a wide range of factory applied facings which include reinforced aluminum foil, fiberglass tissue, black glass tissue and a wide range of imported premium facings Acoustic Insulation values of Glasswool Insulation 48kg/m3-50 mm thick = 0.72 NRC [100 to 8000 Hz.] Mean Temperature in deg C Thermal Conductivity in W/MK Thermal Resistance in sq.m. K/W; Thickness : 50mm 10 0.027 1.85 25 0.030 1.67 30 0.033 1.52 100 0.040 1.25 Temperature Range:- Glasswool is suitable for applications ranging from minus 195°C to 230°C. For special applications up to 450°C, high temperature binder is available. Aluminum foil facing is suitable up to 120°C.

INR 350 INR 350

Availability:True

Pay mode:COD only

view details
BUBBLE INSULATION INR   180 INR  180
-0%

BUBBLE INSULATION

SIPL OPTIMUM Contains DOUBLE layers of FIRE RETARDANT BIG BUBBLE (10mm Thickness x 30 MM Diameter) laminated with both side pure aluminum foil Roll Size (W X L) 1.2m W X 30m L Bubble Size 10MM X 30 MM Nominal Thickness (MM) 20 MM Reflection Ratio >97% Thermal Resistance Emissivity 0.03-0.04 Temperature Range -122 F to 230 F(-50°C ~ 110 °C) SIPL ADVANCE Contains Single layer of FIRE RETARDANT BIG BUBBLE (10mm Thickness x 30 MM Diameter) laminated with both side pure aluminum foil Roll Size (W X L) 1.2m W X 40m Bubble Size 10MM X 30 MM Nominal Thickness (MM) 10 MM Reflection Ratio >97% Thermal Resistance Emissivity 0.03-0.04 Temperature Range -122 F to 230 F(-50°C ~ 110 °C) SIPL Premium contains 2 layers of fire retardant polyethylene air bubble Film laminated with both the side pure aluminum foil. Roll Size (W X L) 1.2m X 40m Bubble Size 4MM X 10 MM Nominal Thickness (MM) 8 MM Reflection Ratio 97% Thermal Resistance Emissivity 0.03-0.04 Temperature Range -122 ℉ to 230 ℉(-50°C ~ 110 °C) SIPL Super contains single layer of fire retardant air bubble film laminated with both side pure aluminum foil. Roll Size (W X L) 1.2m X 40m Bubble Size 4MM X 10 MM Nominal Thickness (MM) 4 MM Reflection Ratio 97% Thermal Resistance Emissivity 0.04-0.05 Temperature Range -122 ℉ to 230 ℉(-50°C ~ 110 °C)

INR 180 INR 180

Availability:True

Pay mode:COD only

view details
"JSW" Colour Coated Roofing Sheets INR   305 INR  305
-0%

"JSW" Colour Coated Roofing Sheets

SIPL–AZS-1 & SIPL-AZS-2 Profile are made from high tensile steel sheets coated with 55% Aluminum, 43.5% Zinc & 1.5% Silicon Alloys. SIPL-GI-3 Profile made of Indian Ultrashine Company with XL Size 4 Feet Width Sheets. BARE GALVALUME ( JSW ) Colour – Natural Silver Coating- AZ150 Base Material – ASTMA792M Grade Class I ( Max. 550 MPa YS ) PRE-PAINTED ( PPGL – JSW ) Colour – Any RAL Color Coating- AZ150 Base Material – ASTMA792M Grade Class I ( Max. 550 MPa YS ) Colour Coating – T/C 18-20 Micron PRE-PAINTED ( PPGI ) ULTRASHINE XL Colour – Any RAL Color Coating- 120 GSM with Guard Film Base Material – ASTMA792M Grade Class I ( Max. 550 MPa YS ) Colour Coating – T/C 18-20 Micron ADVANTEGS: WEATHERPROOF = Long Lasting Protection against extreme weather conditions VARIETY OF COLOURS = Available in a wide range of Colors EASY TO INSTALL = One time easy Installation & require lighter Structure STRENGTH = Lightweight High Tensile Sheets made from Pure Steel Introduction Samirika infrastructure Private Ltd. is a forward integration venture of Samirika Group. Based on the experience of servicing the requirements of some of the leading companies in the country, Samirika had the opportunity to understand the complexities of customer requirements. Based on its experience in understanding the challenges in Supply, Installation and Performance of Roofing and Cladding solutions available in the market over the years, technical team at Samirika decided to take up the challenge of designing the Roofing and Cladding system, which will provide some basic advantages to its customers. • Advantages o Very well defined trapezoidal design. o Design that ensures sturdiness to withstand pressure. o Profile that is elegant and not very complex. o Profile that ensures virtually leak-proof system. o Basic material which are maintenance-free and long-lasting. o Fastening system which can match the international standard. o Delivery of Products as per the given commitments. o Our latest technology driven machines provide us with optimum capacity utilization, thereby making us producer of cost-effective products. Integrated range of products and services. • Results •As a result, Samirika came up to offer its own range of Roofing and Cladding systems which will be offered for its Pre-engineered Building Projects and also offered to its customers for Industrial application. This is first Roll Forming facility in the state of Gujarat. •The flagship company of the group, Samirika infrastucture Pvt. Ltd. is a leading service provider for Erection of Pre-engineered Buildings and Installation of Roofing and Cladding systems for more than 12 years. •As a result, Samirika Group becomes the only group which Manufactures and also undertakes the installation contracts on highly professional terms in the state of Gujarat and one of the very few in the country today. •Standard Accessories List Of Standard Roofing And Cladding Accessories •Cladding Accessories Ridge Cap Ridge Trim •Corner Flashing Gable Trim Eaves Gutter •Valley Gutter Door/Window Flashings Crimp Surved Flashing

INR 305 INR 305

Availability:True

Pay mode:COD only

view details
PRE-ENGINEERING BUILDING INR   88 INR  88
-0%

PRE-ENGINEERING BUILDING

Introduction Pre-engineered Steel Buildings are designed to suit very specific customer requirements. Upon finalizing the requirements, the Primary and Secondary structures are factory-prepared and are assembled at site. The concept is a huge success story in The U.S. and Europe and has made inroads into Indian market less than a decade back. However, most of the production units coming up today are Pre-engineered Steel Buildings. • Ability to span long distances Clear Spans up to 60 mtrs. without internal columns are possible in case of Pre-engineered Buildings. The structure is cost effective. Length is not a constraint. • Flexibility in Building Dimensions The building could be designed as per the specific customer requirement in terms of Length, Width, Height and load Bearing capacity. Tailor made structure enables optimization of cost without undue spending on heavy structure without the need for the same. • Easy Expansion In case of well defined plan in advance, it is possible to have expandable frames which will provide for future expansion, thereby allowing cost spreading over a longer period. • Maintenance-free Exteriors Leakage proof Roofing and Cladding made from 550 mpa high tensile steel coated with Zinc, Aluminium and Silicon Alloy (Galvalume Sheets) for maintenance free exteriors. Also the structure is coated with high quality protective coatings to ensure long maintenance-free interiors and exteriors. • No On-site Fabrication The primary and secondary structure are fabricated and prepared at Samirika Plant and transported to customer site in knocked down conditions. The experienced erection team from Samirika will erect the structure at customer site without any welding operation at site. • Design Accuracy The designing and drafting of Samirika Pre-engineered Buildings is carried out on sophisticated softwares to ensure accuracy of design, development and execution. • Stringent Quality Assurance standards Samirika infrastructure Pvt Ltd follows its Quality System which ensures stringent Quality System in place for Design, Production and erection of Samirika Building Systems. • Faster Project Execution The concept of Pre-engineered Building is based on use of Standards. Right from Design to manufacturing to Erection, standardization of activities make it faster for us to execute a project faster by 30 % of the time it takes to execute a conventional engineering project. • Cost Efficiency The foundations of Pre-engineered Buildings are lighter compared to conventional buildings and also less in number as it is possible to have a wider clear span building. • Adherence to International Standards Building designed and manufactured in accordance with Internationally accepted Standards and Codes like MBMA (Metal Building Manufacturers' Association, AISC (American Institute of Steel Construction Inc. USA) and AISI (American Iron and Steel Institute, USA. • High Aesthetic Appeal Highly qualified design team from Samirika provides various options for designing of structure and also the exteriors of the premises. Accordingly, it is possible for customer to visualize the appearance of the premises even at the concept stage. • Provision for Industrial Ventilation Samirika also manufactures the range of Industrial ventilation solutions which are meant to meet the requirements of Air Ventilation and Natural Light provision. These products are suggested and integrated in the building quote at a very competitive rate making the package complete in all regards. • In-house procurement of Goods and Services to ensure consistency Samirika operates on philosophy of creating value and hence has all the major services and components produced in-house. The design, development, manufacturing of primary structure, secondary structure, roofing & cladding systems, hardware components, ventilation products and erection of the building systems are carried out by Samirika Infrastructure and its own group companies. This ensures adherence to standards set and also helps honouring the timeline commitments with ease. Our Pre-engineered Buildings structures are suitable for a wide range of purposes. • Manufacturing Units / Factories Warehousing Units Supermarkets • Service Stations Restaurants Sports Complexes • Shopping Malls Site Offices Exhibition Halls • Toll Plaza Auditoriums Aircraft Hangers • Retail Outlets Residential Premises Building Width :(BW) BW is defined as the distance from outside of eave strut of one side wall to outside of eave strut of the opposite side wall. Building Length :(BL) BL is defined as the distance between the outside flanges of end wall columns in opposite end walls. The length covers various bay lengths. End Bay Length :(EBL) EBL is the distance from outside of the outer flange of end wall columns to centre line of the first interior frame column. Interior Bay Length :(IBL) BH is defined as the distance from bottom of the main frame column base plate to the top outer point of the eave strut. When columns are recessed or elevated from finished floor, eave height is the distance from finished floor to top of eave strut. Building Height :(BH) IBL is defined as the distance between the centre line of two adjacent interior main frame columns. Most common bay spacings range from 6 metres to 7.5 metres. Design Loads :(DL) Unless otherwise specified, DL considered for Samirika Building Systems are designed for the following minimum loads: Roof Live Load: 0.57 kN/m2 Design Wind Speed: As per IS : 875 for location Design for Snow Loads, Seismic loads, collateral loads or any other local condition need to be specified at the time of designing of the Building. Loads are applied in accordance with the latest American codes and standards applicable to Pre-engineered Metal Buildings unless specified otherwise at the time of designing of the Building.The angle of the roof with respect to the horizontal is termed as RS. The most common roof slope is 1/10. However, Building can be designed with any practical roof slope. Roof Slope(X/10) :(RS) The angle of the roof with respect to the horizontal is termed as RS. The most common roof slope is 1/10. However, Building can be designed with any practical roof slope. #pre-engineering-building-in-anand #pre-engineering-building-in-morbi #pre-engineering-building-in-Nadiad #pre-engineering-building-in-Vapi #pre-engineering-building-in-Surat #pre-engineering-building-in-vadodara

INR 88 INR 88

Availability:True

Pay mode:COD only

view details
1
false